Forum Post: gas gauge for 2 li - ion batteries

hi I need some help in selecting the right gas gauge for my application.I am using 2 li - ion batteries connected in series (i need 7V) but charged separately (because I want to be able to cahrge it...

View Article


Forum Post: RE: BQ77910A recovery from OC (Over Current) and SCD (Short...

Dear WM5295,I examined your comment about the voltage over Vgs.that seems to be the problem!I replaced R41 and R48 to 2 x 200K resistors. which placing a steady ~6V on Vgs.this is a solution for this...

View Article


Forum Post: RE: Not able to change the qmax cell 0 value in bq34z1xx

Thanks Thomas. The device was gone bad, replaced it.I have facing another issue.I am trying to configure the BQ device through the microcontroller. I am able to configure a sublcass with out any...

View Article

Forum Post: bq78pl114 firmware update calibration

if performing firmware-update with bqWizard from bq78pl114 to ...114s12, the voltage calibration has to be explicitly preserved ("... click the Preserve Calibration check box"...).If uploading the...

View Article

Forum Post: RE: BQ20Z75 high current consumption issue

Hi Shirley,I am afraid that's not possible. That current is required for the proper functionality of the gauge.To detect the device is in sleep mode, you need to connect an ammeter to measure the...

View Article


Forum Post: bq3050 / Capacitor on BAT pin

Hi Everyone,I would like to know the impact on the operation of bq3050 if the smaller capacitance than 1uF will be used on BAT pin. I know that the BAT pin will supply power to LDO in bq3050 when...

View Article

Forum Post: BQ24192 charger IC charging current issue ?

Dear All,          We are using BQ24192 in our design. By default charging current should be 2.036mA but when i connect Li-Ion 3800mAh completely discharged battery for charging its taking only 730mA....

View Article

Forum Post: RE: Not able to change the qmax cell 0 value in bq34z1xx

The device does not support switch switching subclasses in the same transmission. You will have to issue a STOP bit and start a new transmission.

View Article


Forum Post: RE: bq3050 / Capacitor on BAT pin

Hi Tom-san,Thank you for your quick response. I understood the purpose of this capacitor. I will request our customer to evaluate by using the capacitance they want to use with their system load.Best...

View Article


Forum Post: CPCKN pulldown design

Hi guys,in bq77908a's datasheet its written down that there are recommended application circuits for the CPCKN pulldown (page 7), when series FETs are used.Can you please send them to me or give me a...

View Article

Forum Post: RE: Bad HF Dynamic Impedance values leading to cell balancing...

Hi Tom,Yes we are working together, but there are some points i want answered.What I don't understand is why are OCV values still approximated/calculated even though the cell has been in a relaxed...

View Article

Forum Post: RE: BQ20Z75 high current consumption issue

Hi Onyx,I see, I'm not too sure on how to perform it. According to the manual of bq20z75, it seems something has to be done with the configuration of NR and NRCHG bits. When NR = 1, upon entering sleep...

View Article

Forum Post: RE: BQ34Z100 & Primary Li-ion Batteries

Thank you Tom

View Article


Forum Post: BQ77910A Constantly drain (balancing) issue

Dear all,I´m running the BQ77910AEVM together with a Li-Ion battery pack which consists of 10 cells connected in series. I got one big issue: When I´m charging or discharging the pack a continuously...

View Article

Forum Post: RE: BQ77910A recovery from OC (Over Current) and SCD (Short...

Glad you found it.  It should not be the Vgs while on that is the issue, but the speed of turn off.The DSG output is a roughly regulated (12V) signal within the Vgs range of common power FETs.R48 and...

View Article


Forum Post: BQ25504 (OK_HYST and OK_PROG pins)

Hello,According to recommendations (http://e2e.ti.com/support/power_management/battery_management/f/179/p/166934/610955.aspx#610955) read in this forum, we have made a BQ25504 electronic design, tying...

View Article

Forum Post: RE: BQ34Z100 - Capacity goes to zero with no load after a day or two

Hi Tom,We were able to capture the data on the problem we are seeing. I attached the log file with line 5435 going from 100% capacity to 0%. We didn't have IT set so that might be part of the problem?...

View Article


Forum Post: RE: BQ77910a stacking - BQ shows Short Circuit Charge flag every...

I noticed that Short Circuit Charge flag appears on both '910a when balancing is on. It doesn't matter which type of balancing is set. Flag appears even when there is no current flowing. (only CHGST...

View Article

Forum Post: RE: Advanced BQMtester HPA495 TIbqMultiStationNB2.18Setup.exe...

To extract the file, I have to put in "ti" as pw. So now everything is fine. I will try the sourcecode tomorrow. Again thank you for your quick response.Regards Max

View Article

Forum Post: RE: The difference of BQ27510-G2 and BQ27510-G3

The change-list is still under development for the bq27510-G3, but it is very similar to the bq27520-G4.I recommend that you look at the bq27520-G4 change list and the bq27520-G4 TRM for more details...