Forum Post: Battery not getting charged

$
0
0

Dear Sir,

We are using BQ24125 in our design for charging Li-ion battery pack with two cells. The battery is not getting charged. We have probed the main signals and given below the details for your reference.

1. CE pin is continuously low.

2. PG pin is continuously low.

3. ISET1 and ISET2 are toggling with a frequency of 1.05Hz with high for a duration of 10ms and low for remaining time.

4. STAT1 is toggling again with a frequency of 1.05Hz with high for a duration of 10ms and low for remaining time.

5. STAT2 is continuosly high.

Please check and let us know on further proceedings.

Regards,

Saravana